SPA8000
Shawn Faas -
Upgrade Firmware
Firmware will be needed to be upgraded in order for the trunking feature to exist as the default firmware doesn't have trunks.
Once logged into the ATAs web GUI:
1) Click on Admin
2) Click on Advanced
3) Click on Voice tab
4) Click on Provisioning
5) Be sure that Upgrade Enable is set to yes
6) Set Upgrade Rule to "tftp.teleflexnet.net/spa8000-6-1-12-XU.bin" Just a future note: "XU" versions exclude SRTP. We don't use SRTP.
7) Click the Submit All Changes button
This process will take a few minutes. Status lights 1-4 will flash randomly and go solid when complete. Refresh the page when lights are solid.
Programming
If not already:
1) Click on Admin
2) Click on Advanced
3) Click on Voice tab
4) Click on T1 tab
5) Update Display Name
6) Enter User ID
7) Enter Password
8) Update Dial Plan with "(*xx|[3469]11|0|00|[2-9]xxxxxx|1xxx[2-9]xxxxxxS0|xxxxxxxxxxxx.)"
9) Update Proxy
10) Submit All Changes
Everything else is default.
Notes
After configuration the full config can be pulled off the device by changing the address to for example "http://172.30.60.218/admin/config.xml" <IP>/admin/config.xml
Copy the contents out and save it in the customer folder as CiscoBackup.xml.
TeleFlex Networks
1510 Primewest Parkway | Suite 800
Katy, TX 77449