SPA8000

Shawn Faas -

Upgrade Firmware

Upgrade Firmware

Firmware will be needed to be upgraded in order for the trunking feature to exist as the default firmware doesn't have trunks.

Once logged into the ATAs web GUI:

1) Click on Admin

2) Click on Advanced

3) Click on Voice tab

4) Click on Provisioning

5) Be sure that Upgrade Enable is set to yes

6) Set Upgrade Rule to "tftp.teleflexnet.net/spa8000-6-1-12-XU.bin" Just a future note: "XU" versions exclude SRTP. We don't use SRTP.

7) Click the Submit All Changes button

This process will take a few minutes. Status lights 1-4 will flash randomly and go solid when complete. Refresh the page when lights are solid.

Programming

Programming

If not already:

1) Click on Admin

2) Click on Advanced

3) Click on Voice tab

4) Click on T1 tab

5) Update Display Name

6) Enter User ID

7) Enter Password

8) Update Dial Plan with "(*xx|[3469]11|0|00|[2-9]xxxxxx|1xxx[2-9]xxxxxxS0|xxxxxxxxxxxx.)"

9) Update Proxy

10) Submit All Changes

Everything else is default.

Line Trunk Groups

Line Trunk Groups

Click on L1 and change the Trunk Group to 1.

Do this for all other additional lines and then Submit All Changes.

Notes

After configuration the full config can be pulled off the device by changing the address to for example "http://172.30.60.218/admin/config.xml"  <IP>/admin/config.xml

Copy the contents out and save it in the customer folder as CiscoBackup.xml.

Have more questions? Submit a request

TeleFlex Networks

1510 Primewest Parkway | Suite 800
Katy, TX 77449